1.
J Indian Med Assoc
;
2007 Jan; 105(1): 37-41
Article
in English
| IMSEAR
| ID: sea-97285
ABSTRACT
To study the safety and efficacy of covered stents in angioplasty of saphenous vein grafts a retrospective study was carried out among 12 consecutive cases admitted at the cardiology unit of Nizam's Institute of Medical Sciences during last 3 years. Angioplasty of saphenous vein grafts is a challenging task due to the different nature of the disease in vein grafts compared to the native coronary arteries. The lesions in vein grafts are more often diffuse and have considerable loose atherothrombotic material that is prone for distal embolisation, resulting in slow flow/no reflow and myocardial damage. Use of covered stents for saphenous vein grafts appears to be feasible and safe.